- Blood volume 0.3 µl
- Measuring time Approx. 5 seconds
- Measuring range 10-600 mg/dl (or 0.6-33.3 mmol/L)
- Measured value memory 2,000 measured values with time and date, average value for 7, 14, 30 and 90 days
- Size 121 x 63 x 20 mm with lancing device
- Weight Approx. 129 g with lancing device, batteries, test cassette and lancet drum
- Measuring method Reflectance photometric determination of glucose from fresh capillary blood. When using other sample materials, please refer to the Accu-Chek Mobile test cassette package insert. The blood glucose monitoring system displays blood glucose values in plasma in accordance with the recommendation of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). Information on how it works, the test principle and the reference measurement method can be found in the Accu-Chek Mobile Test Cassette package insert.
- Humidity during measurement 15 to 85 percent relative humidity
- Humidity during storage 15 to 93 percent relative humidity
- Operating altitude Sea level up to 4000 m above sea level
- Measuring temperature range +10 °C to +40 °C
- Storage temperature of measuring device without batteries and without test cassette: -25 to +70 °C
- Measuring device with batteries and without test cassette: -10 to +50 °C
- Meter with batteries and with test cassette: +2 to +30 °C
- Power supply 2 alkaline manganese or high-energy batteries (1.5 V; type AAA, LR 03, AM 4 or Micro), backup battery: 3 V lithium button cell type CR1025
- Battery performance At least 500 measurements or approx. 1 year (less if the brightness of the display is set to level 3 or the volume is set to level 4 or 5 or in acoustic mode due to the higher power consumption)
- Automatic switch-off After 1 or 2 minute(s), depending on the operating status
- Display OLED display (Organic Light Emitting Diode)
- Interface USB interface
- Protection class III
- LED/IRED class 1
- Electromagnetic compatibility This device meets the requirements for electromagnetic immunity in accordance with EN ISO 15197 Annex A. The basic standard IEC 61000-4-2 was used as the test basis for the immunity tests (for electrostatic discharge). In addition, it meets the requirements for electromagnetic emission in accordance with EN 61326. The electromagnetic emission is correspondingly low. Interference with other electrically operated devices is not to be expected.